These are key areas of the Dr. Dish Software Settings for version 4.0.80 and higher.
Software Menu Settings for Software Version 4.0.80+
If you are having any issues with your Dr. Dish Shooting Machine we always recommend ensuing you are on the most recent version of the software! Follow these instructions to update your software!
Finding Software Versions and Date/Time
- Software Version: More > About
- System Time: More > About
Finding Machine Information
- Serial Number: More > About
- POT Values: More > Support > Troubleshooting > Calibration
- Launch Motor Switch Position > More > Support > Troubleshooting > Diagnostics > Motor Type
Edit Your Court
Move > Settings > Edit Your Court
Calibration
More > Support > Troubleshooting > Calibration > Calibrate
Diagnostic Tests
More > Support > Troubleshooting > Diagnostics
Manual Testing Functions via Software Commands
More > Support > Troubleshooting > Diagnostics > Machine Commands
- Feed: Touch “Feed “and it will cycle the feed motor
- Rotate: Select any of the following and the machine will rotate on it’s own
- Rotate Clockwise
- Rotate Counterclockwise
- Rotate to Center
- The number shown is the left center position POT value
- Rotate to left baseline
- The number shown is the left baseline POT value
- Rotate to right baseline
- The number shown is the right baseline POT value
- Launch: Touch “Launch “and it will cycle the launch motor. You may have to select this twice depending on the position of the launch arm at the time.
If you have an active service ticket you can reply to the last email from our Support+ Team and we will follow up with you! If you do not have a service ticket and require further assistance, please start a service ticket with our Support+ Team or you can call the team at 612-412-4410! We will need the serial number of your machine, your shipping address, and the results of any troubleshooting completed!